Search the Archive
  Home
  Welcome to
  Station Information
  Mathematical and
  Natural Sciences

  Astronomy
  Biology
  Chemistry
  Computer science
  Earth science
  Ecology
  Health science
  Mathematics
  Physics
  Statistics
  Applied Arts
  and Sciences

  Agriculture
 
Architecture
  Business
  Communication
  Education
  Engineering
  Family and
  consumer science

  Government
  Law
  Library and information
  science

  Medicine
  Politics
  Public affairs
  Software engineering
  Technology
  Transport
  Social Sciences
  and Philosophy

  Archaeology
  Economics
  Geography
  History
  History of science
  and technology

  Language
  Linguistics
  Mythology
  Philosophy
  Political science
  Psychology
  Sociology
  Culture and
  Fine Arts

  Classics
  Cooking
  Dance
  Entertainment
  Film
  Games
  Gardening
  Handicraft
  Hobbies
  Holidays
  Internet
  Literature
  Music
  Opera
  Painting
  Poetry
  Radio
  Recreation
  Religion
  Sculpture
  Sports
  Television
  Theater
  Tourism
  Visual arts and design

Gel permeation chromatography


 
In chemistry, Gel Permeation Chromatography (GPC) also known as Size Exclusion Chromatography (SEC) is a chromatographic method in which molecules are separated based on their size. This method is most widely used in the analysis of polymer molecular weights (or molar mass).

In GPC, a column (steel cylinder typically 1cm in diameter and 50 to 100 cm in length) is packed with a porous material (typically silica or crosslinked polystyrene) and solvent is forced through the column at rates typically 1 ml/min and pressures between 1,000 and 4,000 psi. A sample is dissolved in the same solvent that is running through the column and is then introduced into the solvent stream going through the column. A detector monitors the concentration of sample exiting the end of the column. Inside the column, molecules are separated based on their hydrodynamic volume (the volume the molecule occupies in a dilute solution). For polymers this can vary greatly with the particular solvent and the temperature. By studying the properties of polymers in particular solvents and by calibrating each column setup with samples of known molecular weight, it is possible to get a relative distribution of molecular weights for a given polymer sample. Using this data, it is possible to calculate number average molecular weight, weight average molecular weight, polydispersity, as well as higher order molecular weights to within a useful level of accuracy.

Inside the column, molecules are separated by whether or not they can fit within the pore size of the packing material. When columns are created they are packed with porous beads with a specific pore size so that they are most accurate at separating molecules with sizes similar to the pore size. As a molecule flows through the column it passes by a number of these porous beads. If the molecule can fit inside the pore then it is drawn in by the force of diffusion. There it stays a short while and then moves on. If a molecule can not fit into a pore then it continues following the solvent flow. For this reason, in a GPC column, molecules with larger size will reach the end of the column before molecules with smaller size. The effective range of the column is determined by the pore size of the packing. Any molecules larger than all the pores in a column will be eluted together regardless of their size. Likewise, any molecules that can fit into all the pores in the packing material will elute at the same time.

It is important to remember that the only absolute measure in GPC is volume of the molecule, and even that measurement has certain error built into it. Interactions between the solvent, packing, and or the sample will affect the measurement as will concentration due to sample-sample interactions. Calculating the molecular weight from this molecular size introduces even more error into the system. GPC is a usefull tool for determining molecular weight in polymers, but it is essential that the column and instrumentation be carefully equilibrated and properly calibrated for the results to be trusted.